RISH Clamp POWER 1000A/400A measures, calculate and displays important electrical parameters of single phase or three phase power system. It also features Resistance, continuity, diode and non contact voltage detection.
Measures following parameters-
-- AC & DC Voltage upto 1000V
-- AC & DC Current upto 1000A/400 A
-- Inrush/Peak Value Measurement
-- Active, Reactive and Apparent Power
-- Horse Power Measurement
-- kWh
-- Measure up to 49th Harmonics
-- Phase Angle
-- THD
-- DF
-- Power Factor
-- Crest Factor
-- LPF Mode for VFD Application
-- UniqueDesign RISH POWER1000A/400A is a highly Clamp innovative design for features those increasessafety and comfort of user.
- Rotating clamp jaws facilitate the measurement at physically awkward positions, vertical bus bars, conductors placed at positions difficult to access. Clamp jaws can be opened or closed with the trigger placed at bottom side away from the jaws. This allows the user to place his/her hand at safer distance from live conductor. This greatly reduces exposure of human beings to electrical shocks.
- Location and design of trigger eliminates fatigues caused by single finger operation. It allows spreading the force required to open the jaws over more than one finger to ensure comfortable operation. Comfortable operation of push buttons and function selector switch, in adverse field conditions.
Large Jaw Opening - Jaw opening of 51mm and 41mm for standard wire diameter of 50mm and 40mm for 1000A and 400A respectively.
Inrush Current Measurement - Clampmeter will be triggered by inrush current >5A. Inrush current for 100msec is measured.
DATA Hold Function - By pressing DATA HOLD button, reading on the display can be latched for Hands free operation.
MIN, MAX Function - By pressing MIN/MAX button, the clamp meter will start recording latest Minimum and Maximum readings.
Backlit - It is possible to conduct measurement using the clampmeter during poor light condition with the help of bright white light Backlit.
Non Contact Voltage Detection - The clamp meter can detect the presence of AC Voltage between 100 to 1000 V 50hz/60Hz without any electrical connection and give acoustic signal as an indication.
Dual Display - User friendly dual display shows the simultaneous parameters of measuring input quantity.
LPF Mode - LPF mode is available for voltage and current for true measurement of VFD Application
TRMS Measurement - In order to calculate true value of distorted waveform due to presence of high crest factor or harmonics, TRMS measurements is done forAC voltage and current.
Auto Power OFF - In order to save the power of the Batteries, the clamp meter will automatically shut OFF if it detects no activity for 10 minutes.
Continuous ON Mode - In this mode, AUTO POWER OFF is disabled.
Low Battery Indication - Double molded Cover for soft touch and firm grip of the Instrument